Configure request-to-exit devices
Once you have configured your controller, you can further expand your Kisi setup by adding request-to-exit devices to it, e.g. request-to-exit buttons or motion sensors.
For a visual guide on installing the request-to-exit device and configuring it in Kisi, please watch the video below. For step-by-step instructions on configuring the software, use the tabs below.
- Kisi Controller Pro 2
- Kisi Controller Pro 1.1
- Sign in to Kisi
- Navigate to the Place menu and select the place where you want to configure the request-to-exit device for
- Navigate to Hardware in the left-hand menu and select Controllers
- Select the controller that has the request-to-exit device wired to
- Scroll down and click on Inputs
- Select the input that has the request-to-exit wired to
- Under Type, select Request to Exit
- Under Door, select the door the request-to-exit device is wired to
- Under Duration, define how long the relay should be triggered
- Under Action on Access, you have three options:
- Unlock door: If you use a conventional request-to-exit button that directly controls power to the lock, select this option. When triggered, the request-to-exit button will unlock the door immediately.
- Enable unlock: If your request-to-exit device signals the Kisi Controller to control power to the lock (e.g., a motion sensor), select this option. This setting suppresses any "forced open" events for the selected duration. The actual unlock will be controlled by the Kisi Controller, not the request-to-exit device itself.
- Terminate unlock schedule(s): If you want to utilize an interior button exclusively for ending an ongoing Unlock schedule and resetting the First to Arrive schedule, choose this option.
- Under End of Line Type section, specify the desired end-of-line status that you want Kisi to detect:
- Cut detect: Detects if the wiring is cut.
- Short detect: Detects if the wiring is shorted.
- Cut and short detect: Detects both cut and shorted wiring scenarios.
- Enable the toggle
- Click Save
- Sign in to Kisi
- Navigate to the Place menu and select the place where you want to configure the request-to-exit device for
- Navigate to Hardware in the left-hand menu and select Controllers
- Select the controller that has the request-to-exit device wired to
- Scroll down and click on Request to Exit
- Select the input that has the request-to-exit device wired to
- Under Search door, select the door the request-to-exit device is wired to
- Make sure you enable it
- Click Save
info
Cut/short detections will be displayed as Controller tampered
events under Event history.
Remove request-to-exit devices
You can anytime disable your request-to-exit devices using the same Hardware tab.